.General Description:
The TTP301A/TTP301B is an one-decimal electronic clinical thermometer IC. It can push switch to select the
℃/℉ mode.
.Features:
◆ Single 1.5V battery power supply
◆ Automatic power off function
◆ Built-in low voltage detector function
TTP301A:1.30 ± 0.05V
TTP301B:1.35 ± 0.05V
◆ Measurement range: 32.0℃~42.9℃(90.0℉~109.9℉)
◆ Measurement accuracy: ±0.1℃(±0.2℉)
◆ Resolution: 0.1℃(0.1℉)
◆ Highest temperature hold
◆ Provide fever alarm function, enable or disable by bonding option
◆ Bonding option for memory function
◆ Bonding option for stable time selection: 4s/8s/16s/32s
Bonding option for buzzer alarm frequency 4K/5.3K/6.4K/8KHz
◆ Bonding option for ℃ and ℉
◆ Bonding option for ℃/℉ changeable or not change mode by pushing switch
◆ When ℃/℉ changeable mode, push ON/OFF button to select ℃/℉ and bonding option
℃ or ℉ when power on initial
产品中心
.General Description:
The TTP301A/TTP301B is an one-decimal electronic clinical thermometer IC. It can push switch to select the
℃/℉ mode.
.Features:
◆ Single 1.5V battery power supply
◆ Automatic power off function
◆ Built-in low voltage detector function
TTP301A:1.30 ± 0.05V
TTP301B:1.35 ± 0.05V
◆ Measurement range: 32.0℃~42.9℃(90.0℉~109.9℉)
◆ Measurement accuracy: ±0.1℃(±0.2℉)
◆ Resolution: 0.1℃(0.1℉)
◆ Highest temperature hold
◆ Provide fever alarm function, enable or disable by bonding option
◆ Bonding option for memory function
◆ Bonding option for stable time selection: 4s/8s/16s/32s
Bonding option for buzzer alarm frequency 4K/5.3K/6.4K/8KHz
◆ Bonding option for ℃ and ℉
◆ Bonding option for ℃/℉ changeable or not change mode by pushing switch
◆ When ℃/℉ changeable mode, push ON/OFF button to select ℃/℉ and bonding option
℃ or ℉ when power on initial
The TTP301A/TTP301B is an one-decimal electronic clinical thermometer IC. It can push switch to select the
℃/℉ mode.
.Features:
◆ Single 1.5V battery power supply
◆ Automatic power off function
◆ Built-in low voltage detector function
TTP301A:1.30 ± 0.05V
TTP301B:1.35 ± 0.05V
◆ Measurement range: 32.0℃~42.9℃(90.0℉~109.9℉)
◆ Measurement accuracy: ±0.1℃(±0.2℉)
◆ Resolution: 0.1℃(0.1℉)
◆ Highest temperature hold
◆ Provide fever alarm function, enable or disable by bonding option
◆ Bonding option for memory function
◆ Bonding option for stable time selection: 4s/8s/16s/32s
Bonding option for buzzer alarm frequency 4K/5.3K/6.4K/8KHz
◆ Bonding option for ℃ and ℉
◆ Bonding option for ℃/℉ changeable or not change mode by pushing switch
◆ When ℃/℉ changeable mode, push ON/OFF button to select ℃/℉ and bonding option
℃ or ℉ when power on initial
- 详细介绍
- 资料下载
- 样品申请